Aiming at the problems of unbalanced three-phase active power on the distribution network side and large neutral current, the developed active power balance device can balance the three-phase active power of the grid, eliminate the neutral current, increase the resistance of the transformer in the station area, and reduce the line loss. The device is connected in parallel in the low-voltage power grid of the station area, and adopts advanced power electronic technology to redistribute the three-phase active power of the grid without changing the total active power of the load, so as to realize the equal size of the active power and eliminate the neutral line. Current function, so as to achieve the purpose of reducing line loss and improving the utilization of lines and transformers.
■Main power supply voltage measurement: monitoring of over-voltage, under-voltage, power failure, and equal status;
■Backup power supply voltage measurement: monitoring of overvoltage, undervoltage, power failure, and equal status;
■Load current measurement: overcurrent, overload;
■Load residual current measurement: use with residual current transformer
■RS485 communication interface, Modbus-RTU communication protocol
■Standard rail installation: DIN35mm rail
■ Standard rail installation;
■Easy installation, simple wiring, convenient construction and simple debugging;
Parameter Index | |
Input voltage rating | AC 220V |
Input current rating | AC 5A |
Measurement error | <5% |
Power supply | DC 24V |
Power consumption | <1W |
Switch input | Two channels, passive input |
Relay output | AC220V/5A,DC30V/5A |
communication | RS485interface Modbus-RTUprotocol |
Dielectric strength | 2KV |
Insulation resistance | ≥ 50MΩ |
MTBF | ≥ 50000h |
Working conditions | Ambient temperature:-10 ~ + 40℃ Storage temperature:-50℃~ + 85℃ Relative humidity:5% ~ 95%,No condensation |
Installation method | 35mmStandard rail |
Shape size | 106mm*97.6mm*37mm |
Shape size:106*97.6*37mm
Product model
■Main power supply voltage measurement: monitoring of over-voltage, under-voltage, power failure, and equal status;
■Backup power supply voltage measurement: monitoring of overvoltage, undervoltage, power failure, and equal status;
■Load current measurement: overcurrent, overload;
■Load residual current measurement: use with residual current transformer
■RS485 communication interface, Modbus-RTU communication protocol
■Standard rail installation: DIN35mm rail
■ Standard rail installation;
■Easy installation, simple wiring, convenient construction and simple debugging;
Parameter Index | |
Input voltage rating | AC 220V |
Input current rating | AC 5A |
Measurement error | <5% |
Power supply | DC 24V |
Power consumption | <1W |
Switch input | Two channels, passive input |
Relay output | AC220V/5A,DC30V/5A |
communication | RS485interface Modbus-RTUprotocol |
Dielectric strength | 2KV |
Insulation resistance | ≥ 50MΩ |
MTBF | ≥ 50000h |
Working conditions | Ambient temperature:-10 ~ + 40℃ Storage temperature:-50℃~ + 85℃ Relative humidity:5% ~ 95%,No condensation |
Installation method | 35mmStandard rail |
Shape size | 106mm*97.6mm*37mm |
Shape size:106*97.6*37mm
Product model